Product Name: | Cys-C Rapid Test Kit | Sample Buffer: | 25 Vials |
---|---|---|---|
Warranty: | 12 Months | Applicable Instruments: | NIR-1000 Dry Fluorescent Immunoassay Analyzer |
Formal Name: | CystatinC | Storage: | 4-30℃ |
Advantage: | High Accuracy | Manufacturer: | WWHS Biotech INC |
Format: | Cassette | Keywords: | High Stability, High Sensitivity |
High Light: | CystatinC Real Time PCR Kits,ISO13485 Real Time PCR Kits,CysC Fast Test Kit |
【Product name】
Diagnostic Kit for Cystain C(Immunochromatographic assay)
【Package specification】
25 Tests/kit
【Intended use】
It is used to quantitatively detect the content of cystatin C in human serum, plasma and whole blood samples. It is mainly used as one of the indicators reflecting glomerular filtration rate
【Test principle】
The Cys-C Rapid Test is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of Cys-C. The Cys-C antigen in the sample was first bound with the conjugated compound of fluorescent labeled Cys-C monoclonal antibody, then moved and combined with another Cys-C monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.
【Components】
Name | Quantity | Component |
Test cards | 25 | It is composed of fluorescent pad (coated with fluorescent labeled Cys-C monoclonal antibody), nitrocellulose membrane (coated with Cys-C monoclonal antibody and Goat anti mouse IgG antibody), absorbent paper and backing |
Sample diluent | 25(1.50mL/tube) | Phosphate buffer |
ID card | 1 | With specific stand curve file |
The components in different batches of kits cannot be used interchangeably.
【Storage conditions and validity】
The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.
The production date, batch number and expiration date are shown in the outer package of the product.
【Applicable instruments】
NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc
【Sample requirements】
【Test procedure】
【Reference interval】
Healthy non-pregnant adults are expected to have serum Cys-C values 0.5mg/L~1.1mg/L. It is strongly recommended that each laboratory should determine its own normal and abnormal values based on population.
【Interpretation of results】
【Limitations of methods】
【Performance】
1. Limits of detection
No more than 0.40mg/L.
2. Accuracy
The relative deviation from the target value is within ±15%.
3. Precision
The within and between assay coefficient of variations are within 15%.
4. Linear range
Within the linear range (0.40 ~ 9mg/L), the linear correlation coefficient R≥0.990.
【Note】
1. This kit is only used for in vitro diagnosis.
2. The test card and sample diluent are disposable and cannot be reused.
3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.
4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.
5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.
Interpretation of results
1. This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
2. For samples with AFP concentration lower than 2.5ng/ml and higher than 200ng/ml, the detection results are reported as "< 2.5ng/ml" and "> 200ng /ml", respectively.
Limitations of methods
1. This kit is only used to detect human plasma/whole blood samples
2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
3. The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.
4. When the concentration of AFP in the sample is less than 20000ng/ml, there is no hook effect.
5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
6. When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.
Applicable Instrument
WWHS NIR-1000 dry fluoroimmunoassay analyser
Our Service
Pre-sale services:
1. Supply our complete catalogue for your reference.
2 .Help you to learn more details of our equipment.
3. Design and produce the equipment as per your requirement
4. provide diagnostic solution for you
Sales Service:
1. Professional service of the whole exporting processing .
2. Give supporting on your sales chennel establishment of our products.
3. OEM accepted.
After Services:
1. Guarantee for 1 year
2. Quik answer and solution for any problem during your operation
Notice
1) The test card can be used only once at room temperature, do not reuse or use test card out of expiry date.
2) Return all reagents and sample into room temperature before use.
3) Be careful when prepare sample, wear glove and mask.
4) The whole blood need add anticoagulants, not frozen; serum sample can store in frozen, avoid repeated freezing and thawing.
5) This product is only for in vitro rapid diagnostic human use, can be quantified, not only qualitative testing.