WWHS Cov-19 Ag Rapid Test Cassette / Kit FIA POCT Assay Fluorescence Immunoassay

WWHS Cov-19 Ag Rapid Test Cassette / Kit FIA POCT Assay Fluorescence Immunoassay

Cov-19 Ag Rapid Test Cassette

WWHS Ag Rapid Test Cassette

Cov-19 Ag Rapid Test Kit

Place of Origin:

CN

Brand Name:

WWHS

Certification:

ISO13485

Model Number:

SARS Delta Test Kit

Contact Us

Request A Quote
Product Details
Product Name:
Covid-19 Ag Rapid Test Kit
Sample Buffer:
25 Vials
Warranty:
12 Months
Applicable Instruments:
NIR-1000 Dry Fluorescent Immunoassay Analyzer
Package Specification:
25 Tests
Manufacturer:
WWHS Biotech INC
Payment & Shipping Terms
Minimum Order Quantity
1000
Price
US 1.50-2.99 Kit
Packaging Details
Colorful Paper Box
Delivery Time
10 Days
Payment Terms
L/C, T/T
Supply Ability
20000 Kits per Week
Product Description

【Product name】
 SARS-CoV-2 Antigen Rapid Test Kit(Fluorescence immunoassay)
 
【Package specification】
  25 Tests/kit
 
【Intended use】
SARS-CoV-2 Antigen Rapid Test Kit is a lateral flow immunoassay intended for the quantitative detection of the Nucleocapsid antigen from SARS-CoV-2 in nasopharyngeal swabs from individuals who are suspected of SARS-COV-2 by their healthcare provider within the first 7 days of symptom onset, or for screening of individuals without symptoms, or other reasons to suspect SARS-COV-2 infection, if applicable.
Positive results indicate the presence of viral antigens, but clinical correlation with patient history and other diagnostic information is necessary to determine infection status. Positive results do not rule out bacterial infection or co-infection with other viruses. The agent detected may not be the definite cause of disease.
Negative results should be treated as presumptive, and do not rule out SARS-CoV-2 infection and should not be used as the sole basis for treatment or patient management decisions, including infection control decisions. Negative results should be considered in the context of a patient’s recent exposures, history, and the presence of clinical signs and symptoms consistent with SARS-CoV-2, and confirmed with a molecular assay, if necessary, for patient management.
The SARS-COV-2 Antigen Rapid Test Kit is intended for use by trained clinical laboratory personnel specifically instructed and trained in vitro diagnostic procedures.
 
【Inspection principle】
The SARS-CoV-2 Nucleocapsid proteins Rapid Test is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of SARS-CoV-2 Nucleocapsid proteins. The SARS-CoV-2 Nucleocapsid proteins in the sample was first bound with the conjugated compound of fluorescent labeled SARS-CoV-2 Nucleocapsid proteins monoclonal antibody, then moved and combined with another SARS-CoV-2 Nucleocapsid proteins monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.
 
【Components】
 

NameQuantityComponent
Test cards25It is composed of fluorescent pad (coated with fluorescent labeled SARS-CoV-2 Nucleocapsid proteins monoclonal mouse antibody), nitrocellulose membrane (coated with SARS-CoV-2 Nucleocapsid proteins monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent25(400μL/tube)Phosphate buffer
Nasal Mid-Turbinate (NMT) swabs25Flocking
ID card1With specific stand curve file
 

The components in different batches of kits cannot be used interchangeably.
 
【Storage conditions and validity】
The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.
The production date, batch number and expiration date are shown in the outer package of the product.
 
【Applicable instruments】
Nir-1000 dry fluorescent immunoassay analyzer produced by WWHS Biotech. Inc.
 
【Sample requirements】
1.Nasal Mid-Turbinate (NMT) swabs can be used for testing.Venous blood was collected according to routine laboratory methods to avoid hemolysis.
2.Nasal Mid-Turbinate (NMT) swab specimens need to be tested immediately and within 30 minutes of collection.
3.Specimens can be stored at room temperature (15-30 °C) for up to 60 minutes until testing.
 
【Interpretation of results】
1.This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
2.For samples with SARS-CoV-2 Nucleocapsid proteins concentration lower than 0.025ng/ml and higher than 500ng/ml, the detection results are reported as "< 0.025ng/ml" and "> 500ng /ml", respectively.
 
【Note】

  • For in vitro diagnostic use.
  • This test has been authorized only for the detection of SARS-CoV-2 antigen, not for any other viruses or pathogens.
  • Treat all specimens as potentially infectious. Follow universal precautions when handling samples, this kit and its contents.
  • Proper sample collection, storage and transport are essential for correct results.
  • Leave test card sealed in its foil pouch until just before use. Do not use if pouch is damaged or open.
  • Do not use kit past its expiration date.
  • Do not mix components from different kit lots.
  • Do not reuse the used test card.
  • Inadequate or inappropriate sample collection, storage, and transport may yield false test results.
  • Do not store specimens in viral transport media for specimen storage.
  • All components of this kit should be discarded as Biohazard waste according to Federal, State and local regulatory requirements.
  • Solutions used to make the positive control swab are non-infectious. However, patient samples, controls, and test cards should be handled as though they could transmit disease. Observe established precautions against microbial hazards during use and disposal.
  • Wear appropriate personal protection equipment and gloves when running each test and handling patient specimens. Change gloves between handling of specimens suspected of SARS-COV-2.
  • INVALID RESULTS can occur when an insufficient volume of extraction reagent is added to the test card. To ensure delivery of adequate volume, hold vial vertically, ½ inch above the swab well, and add drops slowly.
  • False Negative results can occur if the sample swab is not rotated (twirled) prior to closing the card.
  • Swabs in the kit are approved for use with SARS-COV-2 Ag Card. Do not use other swabs.
  • The Extraction Buffer packaged in this kit contains salts, detergents and preservatives that will inactivate cells and virus particles. Samples eluted in this solution are not suitable for culture.
  • Do not store the swab after specimen collection in the original paper packaging, if storage is needed use a plastic tube with cap.

 


 

 
WWHS Cov-19 Ag Rapid Test Cassette / Kit FIA POCT Assay Fluorescence Immunoassay 0WWHS Cov-19 Ag Rapid Test Cassette / Kit FIA POCT Assay Fluorescence Immunoassay 1
Covid-19 New Self-test Rapid Ag Test Kit
WWHS Cov-19 Ag Rapid Test Cassette / Kit FIA POCT Assay Fluorescence Immunoassay 2
 
 
About WWHS Biotech Inc
 
WWHS Biotech. Inc Is A High-Tech Enterprise Incubated By The Research Institute Of Tsinghua University In Shenzhen In 2016. The Company Is Located In The National Biomedical Industrial Base In Pingshan District, Shenzhen, With About 32,000 Square Feet Space For Workshop And Office.
 
As A Fast-Growing Biotechnology Company, We Dedicate To The Development Of World-Class Bio-Detection Technologies That Meet The Ever-Increasing Demands On Clinical Diagnostics. We Focus On Developing Cost-Effective And Precise Rapid Diagnostic Products Based On Our Unique Near Infrared (NIR) Fluorescence Platform Technologies (PGOLD™ And IR-LF™) With Major Interests In Cardiology, Infectious Diseases, Oncology, Metabolic Diseases And Women And Children’s Health.
 
WWHS Cov-19 Ag Rapid Test Cassette / Kit FIA POCT Assay Fluorescence Immunoassay 3
 
 
Limitations of methods
1. This kit is only used to detect human plasma/whole blood samples
2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
3. The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.
4. When the concentration of AFP in the sample is less than 20000ng/ml, there is no hook effect.
5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
6. When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.

 
 