CEA IVD POCT FIA Rapid Quantitative Test Kit Tumor Marker Detection Blood Diagnostic

CEA IVD POCT FIA Rapid Quantitative Test Kit Tumor Marker Detection Blood Diagnostic

Place of Origin:

CN

Brand Name:

WWHS

Certification:

ISO 13485, CE

Model Number:

CEA

Contact Us

Request A Quote
Product Details
Product Name:
CEA Rapid Quantitative Test Kit
Storage:
Room Temperature
Sample Buffer:
25 Vials
Manufacturer:
WWHS BIOTECH INC
Type:
One Step Assay
Application:
Human
Advantage:
High Sensitivity
Formal Name:
Carcinoembryonic Antigen Rapid Quantitative Test
Package:
20T
Keywords:
High Stability, High Accuracy
Payment & Shipping Terms
Minimum Order Quantity
1000
Price
US 1.50-2.99 Kit
Packaging Details
Colorful Paper Box
Delivery Time
7 Days
Payment Terms
L/C, T/T
Supply Ability
20000 Kits per Week
Product Description

【Product name】

Carcinoembryonic Antigen (CEA) Rapid Quantitative Test(Fluorescence immunoassay)

【Package specification】

25 Tests/kit

【Intended use】

This kit is used for quantitative determination of CEA in human whole blood, plasma and serum.

Carcinoembryonic antigen (CEA) is a tumor associated antigen, first described in 1965 by Gold and Freedman1. It is a cell-surface glycoprotein with a molecular weight of 180-200kD, that occurs in high levels in colon epithelial cells during embryonic development. Levels of CEA are significantly lower in colon tissue of adults, but can become elevated when inflammation or tumours arise in any endodermal tissue, including the gastrointestinal tract, respiratory tract, pancreas and breast.

An over expression of CEA protein has been detected in a variety of adenocarcinomas, including gastric, pancreatic, small intestine, colon, rectal, ovarian, breast, cervical and non-small-cell lung cancers. CEA is also expressed by epithelial cells in several non-malignant disorders, including diverticulitis, pancreatitis, inflammatory bowel disease, cirrhosis, hepatitis, bronchitis and renal failure and also in heavy smokers.

Therefore CEA should not be regarded as a tumour-specific marker for the screening of a general population for undetected cancers. However, the determination of CEA levels provides important information about patient prognosis, recurrence of tumours after surgical removal and effectiveness of therapy.

【Inspection principle】

The CEA Rapid Test is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of CEA. The CEA antigen in the sample was first bound with the conjugated compound of fluorescent labeled CEA monoclonal antibody, then moved and combined with another CEA monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.

【Components】

Name Quantity Component
Test cards 25 It is composed of fluorescent pad (coated with fluorescent labeled CEA monoclonal mouse antibody), nitrocellulose membrane (coated with CEA monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent 25(300μL/tube) Phosphate buffer
ID card 1 With specific stand curve file
 

The components in different batches of kits cannot be used interchangeably.

【Storage conditions and validity】

The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

The production date, batch number and expiration date are shown in the outer package of the product.

【Applicable instruments】

NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.

【Sample requirements】

  1. Plasma, serum and whole blood can be used as samples. The whole blood should be collected in a tube containing heparin, citrate or EDTA as the anticoagulant. If the serum procedure is used, collect blood in a tube without anticoagulant and allow clotting. Hemolyzed samples should not be used.
  2. Venous blood was collected according to routine laboratory methods to avoid hemolysis.
  3. It is highly recommended to use fresh samples instead of keeping the samples at room temperature for a long time. After samples were collected, the detection should be completed within 4 hours at room temperature (15℃~30℃). The whole blood sample can be stored at 2℃~8℃ for 24 hours. Plasma and serum samples can be stored at 2℃~ 8℃ for 7 days, -20℃for 30 days.
  4. Before testing, the sample should return to room temperature (15℃~30℃). The frozen samples should be completely thawed, rewarming and mixed evenly before use. Repeated freeze-thaw cycles should be avoided.

【Procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
  3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
  4. Place the test card on a clean horizontal table and mark it horizontally.
  5. Mix 100µL of patient sample with 300µL of sample diluent. Apply 100µL of diluted samples to the well of the test card.
  6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, read and record the results at 10 minutes after addition of samples, then dispose of used test appropriately.

【Reference interval】

Normal persons who do not smoke: 95% had values less than 5ng/ml. The normal reference value is 5ng/ml in this assay. It is recommended that each laboratory should establish its own normal range based on a representative sampling of the local population.

【Interpretation of results】

  1. This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
  2. For samples with CEA concentration lower than 1ng/ml and higher than 500ng/ml, the detection results are reported as "< 1ng/ml" and "> 500ng /ml", respectively.

【Limitations of methods】

  1. This kit is only used to detect human plasma/whole blood samples
  2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
  3. The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.
  4. When the concentration of CEA in the sample is less than 20000ng/ml, there is no hook effect.
  5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
  6. When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.

【Performance】

1. Limits of detection

No more than 1ng /ml.

2. Accuracy

The relative deviation from the target value is within ±15%.

3. Precision

The within and between assay coefficient of variations are within 15%.

4. Linear range

Within the linear range (1 ~ 500ng/ml), the linear correlation coefficient R≥0.990.

【Note】

1. This kit is only used for in vitro diagnosis.

2. The test card and sample diluent are disposable and cannot be reused.

3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.

5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.

 

CEA IVD POCT FIA Rapid Quantitative Test Kit Tumor Marker Detection Blood Diagnostic 0

 

WWHS Assay list          
 Tumor Marker          
cat#. Product item Specimen Reaction Time Measure Range Clinical Range Itended Use
20 AFP Serum/Plasma 15min. 2.5-200ng/ml <20ng/ml pregnancy cancer
21 CEA Serum/Plasma 15min. 1-200ng/ml <5ng/ml colon cancer, colorectal cancer,etc.
22 NSE Serum/Plasma 15min. 1-400ng/ml <16ng/ml non-small cell lung cancer
23 FOB fecal specimens 10min. 50-1000ng/ml <100ng/ml Abnormal recessive gastrointestinal bleeding
24 PG II Serum/Plasma 15min. 1-100ug/L PGI/PGII>3.0 gastric abnormalities
25 PG I Serum/Plasma 15min. 2.5-200ug/L >70ng/ml gastric abnormalities
26 TPSA Serum/Plasma 15min. 0.5-40ng/ml <4ng/ml prostate cancer
27 FPSA Serum/Plasma 15min. 0.1-10ng/ml <1ng/ml prostate cancer
28 CA12-5 Serum/Plasma 15min. 20-500U/ml <35U/ml ovarian cancer
29 CA15-3 Serum/Plasma 15min. 10-400U/ml < 25 U/mL breast cancer
30 HE4 Serum/Plasma 15min. 50-2000pmol/L <140 pmol/L ovarian cancer
31 CA19-9 Serum/Plasma 15min. 10-400U/ml < 27 U/mL pancreatic cancer
32 β-HCG Serum/Plasma 15min. 5-400mIU/ml <10 mIU/mL Early pregrancy, ectopic HCG cancer,incomplete abortion
33 CK19(Cyfra21-1) Serum/Plasma 15min. 0.5-50ng/ml <2.5ng/ml non-small cell lung cancer

 

CEA IVD POCT FIA Rapid Quantitative Test Kit Tumor Marker Detection Blood Diagnostic 1CEA IVD POCT FIA Rapid Quantitative Test Kit Tumor Marker Detection Blood Diagnostic 2

 

Interpretation of Test Results


1. The kit can be used for auxiliary test only. If test result is abnormal, retest timely and judge combined with clinical symptoms.
2. For samples whose cTnI concentration is lower than 0.1ng/mL and higher than 40ng/mL, test result is “<0.1ng/mL” and “>40ng/mL” respectively.

 

About WWHS FIA Technology

 

Our company's main business is INFRARED fluorescent POCT. The main application scenarios of POCT include emergency department, ICU, chest pain center and stroke center, operating room, and various departments of grade hospitals. Community health, outpatient and other primary medical institutions at all levels; Pharmacies, home use and other organizations and individuals targeted at end customers. POCT is characterized by its simplicity and speed, freedom from application scenarios, and high cost performance. However, the current pain point of POCT industry lies in how to solve the problems of low sensitivity and poor precision faced by POCT products.

 

FAQ

 

Q1: Are you trading company or manufacturer?
A1: We are manufacturer.

 

Q2: Do you provide samples ?
A2: Yes,we do provide samples.If you need it, please contact us.

 

Q3: How about the quality?
A3: We have the best professional engineer and strict QA and QC system to ensure you get high quality products from us.

 

Q4: How’s the package?
A4: Normally are cartons, but also we can pack it according to your requirements.

 

Q5: How’s the delivery time?
A5: It depends on the quantity you need.

 

 

Send your inquiry directly to us