Send Message
Home > products > PCT Rapid Test Kit >
WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood

WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood

Whole Blood One Step Rapid Test Kit

Procalcitonin One Step Test Kit

WWHS One Step Test Kit

Place of Origin:

CN

Brand Name:

WWHS

Certification:

ISO 13485, CE

Model Number:

PCT

Contact Us

Request A Quote
Product Details
Product Name:
Procalcitonin Rapid Test
Storage:
4-30℃
Buffer:
25 Vials
Feature:
High Sensitivity
Application In:
WWHS NIR-1000 Dry Fluoroimmunoassay Analyser
Format:
Cassette
Throughput:
500 Tests/hour
Testing Model:
Timing Test, Quick Test
FIA Manufacturer:
WWHS Biotech INC
Payment & Shipping Terms
Minimum Order Quantity
500
Price
US 1.5-2.50 Kit
Packaging Details
20 Tests in a Paper Box
Delivery Time
7 Days
Payment Terms
L/C, T/T, Western Union
Supply Ability
5000 Kits per Day
Product Description

[Product Name]

Procalcitonin (PCT) Rapid Quantitative Test (Fluorescence immunoassay)

[Packing Specification]

25 Tests/kit

[Intended Use]

The product is used to determine the content of procalcitonin (PCT) in whole blood, plasma and serum of human body and is mainly used clinically for auxiliary diagnosis of bacterial infectious diseases.

[Test Principle]

The kit uses immunochromatographic assay. First, PCT antigen in the sample combines with the fluorescently-labeled PCT monoclonal antibody conjugate. Then, it continues to move and combines with another PCT monoclonal antibody fixed on the nitrocellulose membrane to form double-antibody sandwich immune complex in the position of the nitrocellulose membrane test line and analyze and obtain quantitative test result using NIR-1000 dry fluoroimmunoassay analyser.

[Main Ingredients]

Name Loading capacity Ingredient
Test card 25 The product consists of fluorescent mat (coated with fluorescently-labeled PCT monoclonal murine antibody), nitrocellulose membrane (coated with PCT monoclonal murine antibody and goat anti mouse IgG antibody), absorbent paper and bottom lining.
Sample diluent 25 Phosphate buffer
ID card 1 Record standard curve information of this batch of reagents

Ingredients of kits of different batch numbers cannot be exchanged.

[Storage Conditions and Validity]

The product should be stored at 4℃-30℃ in a dry and dark place, sealed using aluminum foil bag and must not be frozen. The storage life is 12 months. The test card should be unpacked at room temprature (15℃-30℃) and should be used in 15min after unpacked at a temperature of (15-30)℃ and relative humidity of 20%-90%.

See outer packing for production date, batch number and expiry date.

[Applicable Instrument]

NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.

[Sample Requirements]

  1. Serum and EDTA·Na2 anticoagulant plasma and whole blood, EDTA·K2 anticoagulant plasma and whole blood, sodium citrate anticoagulant plasma and whole blood can be used.
  2. Collect venous blood using coventional laboratory method. Clinical samples should be tested at room temperature (15℃-30℃) in 4h after collected. Whole blood specimens can be stored at (2-8)℃ for 24h; serum or plasma specimens can be stored at (2-8)℃ for 7 days and at -20ºC for 30 days.
  3. The sample must be rewarmed to room temperature (15-30)℃ before test. Frozen samples should be completely melted, rewarmed and mixed before use and should not be frozen repeatedly.
  4. Please do not test samples of severe hemolysis, severe lipoidemia and icterus.

[Test Method]

  1. Please thoroughly read the specification before test. Frozen test card and sample should be placed at room temperature (15-30)℃ for at least 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser and verify quality control according to the specification. (Note: Reagent has been calibrated in advance and calibration curve parameters of each batch of reagents have been stored in the information card. Insert the information card before use and carry out test without re-calibration after passing quality inspection; otherwise, identify the cause before test.)
  3. Take out the test card from the aluminum foil bag and use it within 15min
  4. Place the test card on a clean horizontal table top and label it.
  5. Take 100μL of sample and add it into 300μL of buffer solution (1:3). Then, mix the solution evenly, take 100μL of the solution and add it into the test card well.
  6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser and press “Timing test” to keep time for 10min automatically. The analyzer will judge and read the test result automatically and display it in the screen. Or insert the test card into the analyzer after 10min and press “Instant test”, the instrument will judge and read the result automatically.

【Reference Interval】

Determine 254 healthy people aged 18-68 and carry out statistical analysis. Result shows that the upper limit of the reference value is 0.5ng/mL at the 95th percentile, so the reference interval is less than 0.5ng/mL.

The laboratory should establish a reference range according to characteristics of local people.

[Interpretation of Test Results]

1. The kit can be used for auxiliary test only. If test result is abnormal, retest timely and judge combined with clinical symptoms.

2. For samples whose PCT concentration is lower than 0.2ng/mL and higher than 100ng/mL, test result is “<0.2ng/mL” and “>100ng/mL” respectively.

[Limitation of Test Method]

1. The kit can be used to test whole blood, plasma and serum specimens of human body only.

2. Due to limitations of serological methods for antigen and antibody response, the test result cannot be used as the only basis for clinical diagnosis and should be evaluated together with all existing clinical and experimental data.

  1. The content of triglyceride contained in the sample is no more than 10mg/mL, that of hemoglobin is no more than 6mg/mL and that of hemoglobin is no more than 0.6mg/mL, and the relative deviation is limited to ±15%.
  2. When PCT concentration of samples is less than 250ng/mL, Hook effect is not observed.

5. When human anti mouse concentration of samples is less than 50ng/mL, HAMA effect will not be observed.

6. When RF concentration of samples is less than 2000 IU/mL, the test result will not be affected.

[Product Performance Indicators]

  1. Limit of detection

No more than 0.2ng/mL

  1. Accuracy

The relative deviation to the target value is limited to ±15%.

  1. Precision

Within-run precision CV≤15%; between-run relative limit R≤15%.

  1. Linearity range

Within the specified linearity range (0.2-100) ng/mL, linearly dependent coefficient r≥0.990.

【Precautions】

  1. Test card is single-use and it cannot be reused.
  2. Please inspect packaging integrity and validity of kit before use and then unpack the product. If the product is stored at low temperature, restore to room temperature (15℃-30℃) before unpacking and use. Reagent cannot be used if packaging is damaged and the validity period expires.
  3. Take the test card out of the aluminum foil bag and carry out experiment in 15min. Do not place it in the air for a long time to avoid dampness.
  4. It is required to strictly comply with the requirements for sample collection and storage. If the sample is turbid, please centrifuge and precipitate it before use.
  5. The kit contains products from animals. Eligible information about animal source and sanitary condition cannot absolutely ensure inexistence of infectious pathogen. Therefore, these products should be disposed of as latent infective material, and all samples, reagents and latent contaminants should be disinfected and disposed of according to relevant local regulations.
  6. Too high or too low hematocrit of red cells may affect whole blood test result, so verification should be conducted using other methods .

WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood 0WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood 1

 

Assay list          
Cardiac          
cat#. Product item Specimen Reaction Time Measure Range Clinical Range Itended Use
1 cTnI WB/Serum/Plasma 12min. 0.1-40ng/ml <0.3ng/ml several heart diseases including myocardial infarction and heart failure.
2 Myo WB/Serum/Plasma 12min. 5-400ng/ml <58ng/ml acute myocardial infarction (AMI) in early stage.
3 CK-MB WB/Serum/Plasma 12min. 1-200ng/ml <5ng/ml acute myocardial infarction (AMI) in early stage.
4 NT-proBNP WB/Serum/Plasma 10min. 20-35000pg/ml Under 75:0~347pg/mL,
Over 75:0~449pg/mL
heart failure .
5 D-Dimer WB/Plasma 10min. 40-10000ng/ml <500ng/ml disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
6 cTnI+Myo+CKMB WB/Serum/Plasma 12min. same with single item same with single item Triple marker of myocardial infarction.
7 ST2 WB/Serum/Plasma 10min. 10-400ng/ml <35ng/ml heart failure .
8 Lp-PLA2 WB/Serum/Plasma 10min. 10-900ng/ml <175ng/ml Risk evaluation of ACS and atherosclerotic ischemic stroke patients.
9 S100-β WB/Serum/Plasma 10min. 0.05-10ng/ml <0.2ng/ml Cerebral infarction, cerebral injury.
Inflammation          
10 CRP / hs-CRP WB/Serum/Plasma 3min. 0.5-200mg/L CRP<10mg/L,hs-CRP<1mg/L nonspecficity inflammatory marker.
11 SAA Serum 5min. 1-200mg/L <10mg/L inflammation&infection.
12 PCT WB/Serum/Plasma 10min. 0.2-100ng/ml <0.5ng/ml Sepsis
13 CRP+SAA WB/Serum/Plasma 5min. same with single item same with single item inflammation&infection.
14 IL-6 WB/Serum/Plasma 10min. 5-4000pg/ml 10pg/ml diabetes,rheumatoid arthritis,etc
Thyroid Hormone          
15 TSH Serum/Plasma 15min. 0.3-100mU/L 0.35-5mU/L hyperthyroidism and hypothyroidism
16 TT3 Serum/Plasma 15min. 0.5-10nmol/L 1.3-3.1nmol/L thyroid dysfunction
17 TT4 Serum/Plasma 15min. 5-300nmol/L 66-181nmol/L thyroid dysfunction
18 FT3 Serum/Plasma 15min. 1-100pmol/L 4-10pmol/L thyroid dysfunction
19 FT4 Serum/Plasma 15min. 5-300pmol/L 19-39pmol/L thyroid dysfunction
Tumor Maker          
20 AFP Serum/Plasma 15min. 2.5-200ng/ml <20ng/ml pregnancy cancer
21 CEA Serum/Plasma 15min. 1-200ng/ml <5ng/ml colon cancer, colorectal cancer,etc.
22 NSE Serum/Plasma 15min. 1-400ng/ml <16ng/ml non-small cell lung cancer
23 FOB fecal specimens 10min. 50-1000ng/ml <100ng/ml Abnormal recessive gastrointestinal bleeding
24 PG II Serum/Plasma 15min. 1-100ug/L PGI/PGII>3.0 gastric abnormalities
25 PG I Serum/Plasma 15min. 2.5-200ug/L >70ng/ml gastric abnormalities
26 TPSA Serum/Plasma 15min. 0.5-40ng/ml <4ng/ml prostate cancer
27 FPSA Serum/Plasma 15min. 0.1-10ng/ml <1ng/ml prostate cancer
28 CA12-5 Serum/Plasma 15min. 20-500U/ml <35U/ml ovarian cancer
29 CA15-3 Serum/Plasma 15min. 10-400U/ml < 25 U/mL breast cancer
30 HE4 Serum/Plasma 15min. 50-2000pmol/L <140 pmol/L ovarian cancer
31 CA19-9 Serum/Plasma 15min. 10-400U/ml < 27 U/mL pancreatic cancer
32 β-HCG Serum/Plasma 15min. 5-400mIU/ml <10 mIU/mL Early pregrancy, ectopic HCG cancer,incomplete abortion
33 CK19(Cyfra21-1) Serum/Plasma 15min. 0.5-50ng/ml <2.5ng/ml non-small cell lung cancer
Fertility          
34 HCG / β-HCG Serum/Plasma 10min. 5-20000mIU/ml <5 mIU/mL early pregrancy.
35 AMH Serum/Plasma 10min. 0.1-16ng/ml Male: 20-60 years old, 0.92-13.89 ng/mL
Female: 20-29 years old, 0.88-10.35 ng/mL
30-39 years old, 0.31-7.86 ng/mL 40 -50 years old, <5. 07 ng/mL
ovarian reserve level
Gastrointestinal            
36 FOB fecal specimens 10min. qualitative qualitative gastrointestinal hemorrhage.
37 TRF fecal specimens 10min. qualitative qualitative gastrointestinal hemorrhage.
38 FOB+TRF fecal specimens 10min. qualitative qualitative gastrointestinal hemorrhage.
Infection            
39 C.Pneumonia WB/Serum/Plasma 15min. qualitative qualitative CP infection
40 M.Pneumonia WB/Serum/Plasma 15min. qualitative qualitative MP infection
41 Covid-19 Antigen nasal swab, throat swab or nasal wash/aspirate specimens 15min. qualitative qualitative respiratory tract
42 Covid-19 Ab IgG/IgM WB/Serum/Plasma 15min. qualitative qualitative respiratory tract
43 FluA nasal swab, throat swab or nasal wash/aspirate specimens 15min. qualitative qualitative respiratory tract
44 FluB nasal swab, throat swab or nasal wash/aspirate specimens 15min. qualitative qualitative respiratory tract
Renal Injury            
45 CysC WB/Serum/Plasma 5min. 0.4-9mg/L 0.5-1.1mg/L renal function
46 NGAL Urine 10min. 10-1500ng/mL <132ng/mL acute kidney injury.
Other            
47 FERR Serum 5min. 10-500ng/ml Male:24ng/mL~335ng/mL,
Female:11ng/mL~307ng/mL
iron metabolism related diseases, such as hemochromatosis and iron deficiency anemia
48 HbA1c WB 10min. 4%-14% 4%-6% diabetes
49 VD Serum/Plasma 15min. 8-70ng/mL 19-57ng/mL fetation

 

WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood 2WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood 3

 

Storage Conditions and Validity


The product should be stored at 4℃-30℃ in a dry and dark place, sealed using aluminum foil bag and must not be frozen. The storage life is 12 months. The test card should be unpacked at room temprature (15℃-30℃) and should be used in 15min after unpacked at a temperature of (15-30)℃ and relative humidity of 20%-90%.
See outer packing for production date, batch number and expiry date.

 

Why Choose Us

 

Our company's main business is INFRARED fluorescent POCT. The main application scenarios of POCT include emergency department, ICU, chest pain center and stroke center, operating room, and various departments of grade hospitals. Community health, outpatient and other primary medical institutions at all levels; Pharmacies, home use and other organizations and individuals targeted at end customers. POCT is characterized by its simplicity and speed, freedom from application scenarios, and high cost performance. However, the current pain point of POCT industry lies in how to solve the problems of low sensitivity and poor precision faced by POCT products.


1. Precision
Deviation is less than 3.0%
2. Upgraded data storage
10000 data storage
3. Long life
Support to use 3 years

 

FAQ:

 

1. What is the MOQ?

 

Generally if you choose the different products, our minimum order qty. also will be different. One sample available.

 

2. What about the delivery time?

 

The goods need 7-21 work days to be made upon deposit.

 

3. Does your product have any warranty?

 

Yes, we offer 6 months limited warranty for our products.

 

Damage due to misuse, ill treatment and unauthorized modifications and repairs are not covered by our warranty.

 

4. What's your payment method?

 

We usually accept the payment methods include PayPal, TT, and Western Union.

 

50% deposit in advance and balance before shipping. Buyer can choose which payment ways that you accept.

 

PayPal is most useful and safe, please don’t refuse PayPal fee when you choose PayPal.

 

5. What's your shipping method?

 

We provide comprehensive shipping methods.

 

For small quantity orders we ship by DHL Air-Express, or EMS/TNT/UPS/FEDEX Express service, it is safe and fast.

 

For large quantity orders we ship by Air transportation or sea transportation, we can also ship order to buyer’s cargo agent in China.

 

Applicable Instrument


NIR-1000 dry fluoroimmunoassay analyser produced by Shenzhen WWHS Biotechnology Co., Ltd.

 

Send your inquiry directly to us

Privacy Policy China Good Quality POCT Test Kit Supplier. Copyright © 2021-2024 fiapoct.com . All Rights Reserved.