Diagnostic Kit for Haemoglobin A1c(Immunochromatographic Assay)
Ⅰ.About our product
Product Name:Diagnostic Kit for Haemoglobin A1c(Immunochromatographic Assay)
Intended Use:The kit is used for quantitative determination of HbA1c in human whole blood,and is mainly used for diagnosis of diabetes and monitoring of blood glucose level clinically.
Components:
Name | Quantity | Component |
Test cards | 25/40 | The product consists of fluorescent mat (coated with fluorescently-labeled HbA1c mouse antibody), nitrocellulose membrane (coated with HbA1c mouse antibody and Goat anti mouse IgG antibody), absorbent paper and PVC soleplate, and so on. |
Sample diluent | 25/40 | Phosphate buffer |
ID card | 1 | With specific stand curve file |
The components in different batches of kits cannot be used interchangeably.
Test Method:
1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
2. Start NIR-1000 dry fluorescence immunoassay analyzer according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
4. Place the test card on a clean horizontal table and mark it horizontally.
5. Take 10μL of sample and add it into HbA1c sample buffer (1.00mL). After mixing thoroughly the solution for 1 min, take 100μL of the solution and add it into the well.
6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, keep time for 10min and press 【Instant test】. The analyser will judge and read the test result automatically. Or press 【Fixed time test】 to keep time for 10min automatically. The analyser will judge and read the test result automatically and display it in the screen.
Ⅱ.Why to choose us?
Product Performance Indicators:
1. Limits of detection
No higher than 4.0%.
2. Accuracy
The relative deviation to the target value is limited to ±10.0%.
3. Repeatability
Coefficient of variations are within 10%.
4. Batch-to-batch difference
The relative range (R) between batches shall not be greater than 15.0%.
5. Linearity range
Within the specified linearity range 【4.0%,14.0%】:
a) Linearly dependent coefficient (r) is no less than 0.9900;
b) Within 【4.0%,6.0%】, linear absolute deviation is limited to ±0.6%.
Within 【6.0%,14.0%】, linear absolute deviation is limited to ±10.0%.
repairs are not covered by our warranty.
4. What's your payment method?
We usually accept the payment methods include PayPal, TT, and Western Union.
50% deposit in advance and balance before shipping. Buyer can choose which payment ways that you accept.
PayPal is most useful and safe, please don’t refuse PayPal fee when you choose PayPal.
5. What's your shipping method?
We provide comprehensive shipping methods.
For small quantity orders we ship by DHL Air-Express, or EMS/TNT/UPS/FEDEX Express service, it is safe and fast.
For large quantity orders we ship by Air transportation or sea transportation, we can also ship order to buyer’s cargo agent in China.
Send your inquiry directly to us