Product Name:
PGII Tumor Marker
Sample Buffer:
25 Vials
Linearity Range:
Within The Specified Linearity Range (4.0%,14.0%)
Storage:
Room Temperature
Warranty:
12 Months
Applicable Instrument:
NIR-1000 Dry Fluoroimmunoassay Analyser
Packaging:
25 Tests
Feature:
High Sensitivity, High Accuracy
Payment & Shipping Terms
Minimum Order Quantity
1000
Price
US 1.50-2.50 Kit
Packaging Details
Colorful Paper Box
Delivery Time
7 Days
Payment Terms
L/C, T/T
Supply Ability
50000 Kits per Week
Product Description

PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T


PGI/PGII Rapid Quantitative Test Human pepsinogens I (PGI) and II (PGII) are proenzymes of pepsin—an

endoproteinase of gastric juice. PGI is secreted mainly by chief cells in the fundic mucosa, whereas

PGII is also secreted by the pyloric glands and the proximal duodenal mucosa.

 

Name Loading Capacity Component
Test Card 25 Persons  The product consists of fluorescent mat (coated with fluorescently-labeled   PGII antibody), nitrocellulose membrane (coated with PGII antibody), absorbent paper and PVC soleplate,   and so on.
Sample Buffer 25 vials (0.3mL/vial)  Phosphate buffer
Information Card 1 Piece  Record standard curve information of this batch of reagents

 

WWHS Assay Items

 

 Tumor Marker          
cat#. Product Item Specimen Reaction Time Measure Range Clinical Range Intended Use
20 AFP Serum/Plasma 15min. 2.5-200ng/ml <20ng/ml pregnancy cancer
21 CEA Serum/Plasma 15min. 1-200ng/ml <5ng/ml colon cancer, colorectal cancer,etc.
22 NSE Serum/Plasma 15min. 1-400ng/ml <16ng/ml non-small cell lung cancer
23 FOB fecal specimens 10min. 50-1000ng/ml <100ng/ml Abnormal recessive gastrointestinal bleeding
24 PG II Serum/Plasma 15min. 1-100ug/L PGI/PGII>3.0 gastric abnormalities
25 PG I Serum/Plasma 15min. 2.5-200ug/L >70ng/ml gastric abnormalities
26 TPSA Serum/Plasma 15min. 0.5-40ng/ml <4ng/ml prostate cancer
27 FPSA Serum/Plasma 15min. 0.1-10ng/ml <1ng/ml prostate cancer
28 CA12-5 Serum/Plasma 15min. 20-500U/ml <35U/ml ovarian cancer
29 CA15-3 Serum/Plasma 15min. 10-400U/ml < 25 U/mL breast cancer
30 HE4 Serum/Plasma 15min. 50-2000pmol/L <140 pmol/L ovarian cancer
31 CA19-9 Serum/Plasma 15min. 10-400U/ml < 27 U/mL pancreatic cancer
32 β-HCG Serum/Plasma 15min. 5-400mIU/ml <10 mIU/mL Early pregrancy, ectopic HCG cancer,incomplete abortion
33 CK19(Cyfra21-1) Serum/Plasma 15min. 0.5-50ng/ml <2.5ng/ml non-small cell lung cancer

 

PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T 0PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T 1PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T 2PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T 3PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T 4

PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T 5PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T 6

PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T 7PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T 8

 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quality Control

 

A procedural control is included in the test. A colored line appearing in the control region (C) is the internal procedural
control. It confirms sufficient specimen volume and correct procedural technique.
Control standards are not supplied with this kit; however, it is recommended that a positive control and a negative control control be tested as a good laboratory practice to confirm the test procedure and to verify proper test performance.

 

Test Method

 

1. Please thoroughly read the specification before test. Frozen test card and sample should be placed at room temperature (15-30) ℃ for at least 30min before use.
2. Start NIR-1000 dry fluoroimmunoassay analyser and verify quality control according to the specification.
3. The quality of reagent is controlled using internal quality control product (not provided) of the company and result should be controllable.
4. Take out the test card from the aluminum foil bag and use it within 15min
5. Place the test card on a clean horizontal table top and label it.
6. Take 10μL of sample and add it into HbA1c sample buffer (1.00mL). Then, mix the solution evenly, take 100μL of the solution and add it into the well.
7. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, keep time for 10min and press 【Instant test】. The analyser will judge and read the test result automatically. Or press 【Fixed time test】 to keep time for 10min automatically. The analyser will judge and read the test result automatically and display it in the screen.


Applicable Instrument


WWHS NIR-1000 dry fluoroimmunoassay analyser