Send Message
Home > products > Cardiac Testing Kit >
DD D-Dimer Rapid Quantitative Test , Blood Rapid Diagnostic Test Kit

DD D-Dimer Rapid Quantitative Test , Blood Rapid Diagnostic Test Kit

D-Dimer Rapid Quantitative Test

DD Rapid Diagnostic Test Kit

Place of Origin:

CN

Brand Name:

WWHS

Certification:

CE

Model Number:

DD

Contact Us

Request A Quote
Product Details
Product Name:
D-Dimer Rapid Quantitative Test
Package:
25T
Storage:
At Room Temperature
Application In:
WWHS NIR-1000 Dry Fluoroimmunoassay Analyser
Reactivity:
Human
Advantage:
High Accuracy
Feature:
High Sensitivity
Supply Capacity:
5 Million A Year
Payment & Shipping Terms
Minimum Order Quantity
1000
Price
US 1.50 - 2.50 Kit
Packaging Details
Colorful Paper Box
Delivery Time
7 Days
Payment Terms
T/T
Supply Ability
50000 Kits per Week
Product Description

【Product name】

D-Dimer Rapid Quantitative Test(Fluorescence immunoassay)


【Package specification】

20 Tests/box


Performance】

1. Analysis sensitivity

No more than 40ng/ml.

2. Accuracy

The relative deviation from the target value is within ±15%.

3. Precision

The within and between assay coefficient of variations are within 15%.

4. Linear range

Within the linear range (40 ~ 10000ng/ml), the linear correlation coefficient R≥0.990.


【Main components】

Name Quantity Component
Test card 25 It is composed of fluorescent pad (coated with fluorescent labeled D-dimer monoclonal mouse antibody), nitrocellulose membrane (coated with D-dimer monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample buffer 25(300μL/tube) Phosphate buffer
ID card 1 Record the standard curve information of this kit
 

The components in different batches of kits cannot be used interchangeably.


【Storage conditions and validity】

The test card should be stored at 4℃~30℃, dry, dark and no freezing. It should be stored in sealed aluminum foil bag and valid for 12 months. The test card should be returned to room temperature (15℃~30℃) before opening. It should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

The production date, batch number and expiration date are shown in the outer package of the product.

 

【Procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed; Otherwise, the cause should be found out before testing.)
  3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
  4. Place the test card on a clean horizontal table and mark it horizontally.
  5. Mix 10 µL of patient sample with 300µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
  6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, press the [timing detection] key, automatically time for 10 minutes, automatically judge the test results, and display the quantitative results on the screen. Or insert the test card into the analyzer after timing for 10 minutes, and press the [real time detection] key, and the instrument will automatically interpret the test results.

【Note】

1. This kit is only used for in vitro diagnosis.

2. The test card and sample diluent are disposable and cannot be reused.

3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃~30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.

5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.

DD D-Dimer Rapid Quantitative Test , Blood Rapid Diagnostic Test Kit 0

 

Note:


1) Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in
result. Each user should obtain their own standard curve.
2) If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
3) If specimens generate values higher than the highest standard, dilute the specimens and repeat the assay

 

Assay list          
Cardiac          
cat#. Product Item Specimen Reaction Time Measure Range Clinical Range Intended Use
1 cTnI WB/Serum/Plasma 12min. 0.1-40ng/ml <0.3ng/ml several heart diseases including myocardial infarction and heart failure.
2 Myo WB/Serum/Plasma 12min. 5-400ng/ml <58ng/ml acute myocardial infarction (AMI) in early stage.
3 CK-MB WB/Serum/Plasma 12min. 1-200ng/ml <5ng/ml acute myocardial infarction (AMI) in early stage.
4 NT-proBNP WB/Serum/Plasma 10min. 20-35000pg/ml Under 75:0~347pg/mL,
Over 75:0~449pg/mL
heart failure .
5 D-Dimer WB/Plasma 10min. 40-10000ng/ml <500ng/ml disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
6 cTnI+Myo+CKMB WB/Serum/Plasma 12min. same with single item same with single item Triple marker of myocardial infarction.
7 ST2 WB/Serum/Plasma 10min. 10-400ng/ml <35ng/ml heart failure .
8 Lp-PLA2 WB/Serum/Plasma 10min. 10-900ng/ml <175ng/ml Risk evaluation of ACS and atherosclerotic ischemic stroke patients.
9 S100-β WB/Serum/Plasma 10min. 0.05-10ng/ml <0.2ng/ml Cerebral infarction, cerebral injury.

 

 

 

Advantage:

 

1. Advanced Quality: We have strict quality control system and enjoy good reputation in the market.

2. Sincerly Service: We treat clients as friend and aims at building long term business relatiionship.

 

FAQ:


Q. How is your company's product after-sales service system?
A. The product warranty period is 12 months, we can provide lifetime maintenance. We have professional pre-sales and after-sales teams that can respond to you within 24 hours to resolve technical issues. We provide one-to-one after-sales service.

 

Q: Can you customize it?
A: Yes, we accept customization according to customer's specific requirements.

 

Q. How long is your lead time? If I want to customize instruments, how long will it take?
A. When order quantity is 1-10 units, we have ready stock goods, we can ship out within 3-5 working days after receipt of deposit; products required new production of common materials, usually the lead time is about 10-15 days; products requiring new production of special and rare materials, usually the lead time is about 20-30 days.

Most Of FIA Rapid Test Cassette Assay Such As Cardiac and Inflammation Items Are Available For 5-10 days Prompt Shipment.

 

Q. What payment method do you accept?
A. Our company accept payment method of T/T (bank transfer), Western Union, PayPal and so on.

 

Q. What package do you use for your products? What shipping method do you use?
A.1. Our company use standard exporting carton for packing. 2. We ship via express courier (door to door service), by air, and by sea according to customers' requirements.

 

For more questions, please feel free to send inquiries to us.

Send your inquiry directly to us

Privacy Policy China Good Quality POCT Test Kit Supplier. Copyright © 2021-2024 fiapoct.com . All Rights Reserved.