Product Name:
Cys-C Rapid Quantitative Test Kit
Shelf Life And Storage Temperature:
12 Months At 4-30°C
Manufacturer:
WWHS Biotech INC
Advantage:
High Sensitivity
Reactivity:
Human
Formal Name:
CystatinC
Feature:
High Sensitivity
Supply Capacity:
3 Million A Year
Payment & Shipping Terms
Minimum Order Quantity
1000
Price
US 1.50 - 2.50 Kit
Packaging Details
Colorful Paper Box
Delivery Time
7 Days
Payment Terms
T/T
Supply Ability
50000 Kits per Week
Product Description

【Product name】

Diagnostic Kit for Cystain C(Immunochromatographic assay)

 

【Package specification】

25 Tests/kit

 

【Intended use】

It is used to quantitatively detect the content of cystatin C in human serum, plasma and whole blood samples. It is mainly used as one of the indicators reflecting glomerular filtration rate

 

【Test principle】

The Cys-C Rapid Test is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of Cys-C. The Cys-C antigen in the sample was first bound with the conjugated compound of fluorescent labeled Cys-C monoclonal antibody, then moved and combined with another Cys-C monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.

 

【Components】

Name Quantity Component
Test cards 25 It is composed of fluorescent pad (coated with fluorescent labeled Cys-C monoclonal antibody), nitrocellulose membrane (coated with Cys-C monoclonal antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent 25(1.50mL/tube) Phosphate buffer
ID card 1 With specific stand curve file
 

The components in different batches of kits cannot be used interchangeably.

 

【Storage conditions and validity】

The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

The production date, batch number and expiration date are shown in the outer package of the product.

 

【Applicable instruments】

NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc

 

【Sample requirements】

  1. Plasma, serum and whole blood can be used as samples. The whole blood should be collected in a tube containing heparin, citrate or EDTA as the anticoagulant. If the serum procedure is used, collect blood in a tube without anticoagulant and allow clotting. Hemolyzed samples should not be used.
  2. Venous blood was collected according to routine laboratory methods to avoid hemolysis.
  3. It is highly recommended to use fresh samples instead of keeping the samples at room temperature for a long time. After samples were collected, the detection should be completed within 4 hours at room temperature (15℃~30℃). The whole blood sample can be stored at 2℃~8℃ for 24 hours. Plasma and serum samples can be stored at 2℃~ 8℃ for 7 days, -20℃for 30 days.
  4. Before testing, the sample should return to room temperature (15℃~30℃). The frozen samples should be completely thawed, rewarming and mixed evenly before use. Repeated freeze-thaw cycles should be avoided.

 

【Test procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser and correctly select the corresponding sample type on the instrument.
  3. Take out the ID card, make sure that the batch number of the ID card is consistent with that of the test card, and insert the ID card into the ID card port of the instrument.
  4. Take out the test card from the aluminum foil bag and use it within 15 minutes.
  5. Place the test card on a clean horizontal table and mark it horizontally.
  6. Mix 5µL of sample with 1.50mL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
  7. At 5 minutes after addition of samples, insert the test card into NIR-1000 dry fluoroimmunoassay analyser and click the “Instant test” button to read the results.

 

【Reference interval】

Healthy non-pregnant adults are expected to have serum Cys-C values 0.5mg/L~1.1mg/L. It is strongly recommended that each laboratory should determine its own normal and abnormal values based on population.

 

【Interpretation of results】

  1. This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
  2. For samples with Cys-C concentration lower than 0.4mg/L and higher than 9mg/L, the detection results are reported as "<0.4mg/L" and ">9mg/L", respectively.

 

【Limitations of methods】

  1. This kit is only used to detect human plasma/whole blood samples
  2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
  3. The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.
  4. When the concentration of Cys-C in the sample is less than 15mg/L, there is no hook effect.
  5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
  6. When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.

 

【Performance】

1. Limits of detection

No more than 0.40mg/L.

2. Accuracy

The relative deviation from the target value is within ±15%.

3. Precision

The within and between assay coefficient of variations are within 15%.

4. Linear range

Within the linear range (0.40 ~ 9mg/L), the linear correlation coefficient R≥0.990.

 

【Note】

1. This kit is only used for in vitro diagnosis.

2. The test card and sample diluent are disposable and cannot be reused.

3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.

5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.

 

 

Cystatin C Real Time PCR Kits High Sensitivity 12 Months Shelf life 0

 

Note:


1) Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in
result. Each user should obtain their own standard curve.
2) If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
3) If specimens generate values higher than the highest standard, dilute the specimens and repeat the assay

 

Assay list  Renal Injury        
cat#. Product item Specimen Reaction Time Measure Range Clinical Range Itended Use
45 CysC WB/Serum/Plasma 5min. 0.4-9mg/L 0.5-1.1mg/L renal function
46 NGAL Urine 10min. 10-1500ng/mL <132ng/mL acute kidney injury.

 

Cystatin C Real Time PCR Kits High Sensitivity 12 Months Shelf life 1Cystatin C Real Time PCR Kits High Sensitivity 12 Months Shelf life 2Cystatin C Real Time PCR Kits High Sensitivity 12 Months Shelf life 3

 

Advantage:

 

1. Advanced Quality: We have strict quality control system and enjoy good reputation in the market.

2. Sincerly Service: We treat clients as friend and aims at building long term business relatiionship.

 

More options, Click the following link if any interest

 

Fertility Test

Hepatitis Rapid Test

Tropical Diseases Test

Respiratory & Digestive Disease Test

Sexually Transmitted Diseases Test

Tumor Markers Test

Cardiac Marker Test

Inflammatory Marker Test

Drug Abuse Test

Renal injury Test

Protein Markers Test

Autoimmune Diseases Test

 

FAQ:

 

1. What is the MOQ?

 

Generally if you choose the different products, our minimum order qty. also will be different. One sample available.

 

2. What about the delivery time?

 

The goods need 7-21 work days to be made upon deposit.

 

3. Does your product have any warranty?

 

Yes, we offer 6 months limited warranty for our products.

 

Damage due to misuse, ill treatment and unauthorized modifications and repairs are not covered by our warranty.

 

4. What's your payment method?

 

We usually accept the payment methods include PayPal, TT, and Western Union.

 

50% deposit in advance and balance before shipping. Buyer can choose which payment ways that you accept.

 

PayPal is most useful and safe, please don’t refuse PayPal fee when you choose PayPal.

 

5. What's your shipping method?

 

We provide comprehensive shipping methods.

 

For small quantity orders we ship by DHL Air-Express, or EMS/TNT/UPS/FEDEX Express service, it is safe and fast.

 

For large quantity orders we ship by Air transportation or sea transportation, we can also ship order to buyer’s cargo agent in China.

 

Disclaimer

 

While every efforts were made to ensure the accuracy of the information provided in this datasheet, FIA POCT will not be liable for any omissions or errors contained herein. FIA POCT reserves the right to make changes to this datasheet at any time without prior notice.

 

All of WWHS's Products are for scientific laboratory research purposes and diagnostic, therapeutics analysis, and are not for prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to WWHS that you will properly test and use any Products purchased from WWHS in accordance with industry standards. WWHS and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.

 

Send your inquiry directly to us

Privacy Policy China Good Quality POCT Test Kit Supplier. Copyright © 2021-2024 fiapoct.com . All Rights Reserved.