【Product name】
Diagnostic Kit for Interleukin-6(Immunochromatographic assay)
【Packing specification】
25 Tests/kit
【Components】
Name | Quantity | Component |
Test cards | 25 | It is composed of fluorescent pad (coated with fluorescently-labeled IL-6 monoclonal antibody), nitrocellulose membrane (coated with IL-6 monoclonal antibody and Goat anti mouse IgG antibody), absorbent paper and backing. |
Sample diluent | 25 (0.3mL/ tube) | Phosphate buffer |
ID card | 1 | With specific stand curve file |
The components in different batches of kits cannot be used interchangeably.
【Storage conditions and validity】
The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.
The production date, batch number and expiration date are shown in the outer package of the product.
【Test procedure】
【Performance】
1. Limits of detection
No higher than 5.00 pg/mL.
2. Accuracy
The relative deviation from the target value is limited to ±15.0%.
3. Repeatability
The within and between assay coefficient of variations are within 15.0%.
4. Linearity range
Within the linear range (5.00~ 4000.00)ng/mL, the linear correlation coefficient R≥0.990.
【Note】
1. The kit can be used for in vitro diagnosis only.
2. Test card and buffer solution are single-use and they cannot be reused.
3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.
4. Take the test card out of the aluminum foil bag and carry out experiment in 15min. Do not place it in the air for a long time to avoid dampness.
5. It is required to strictly comply with the requirements for sample collection and storage. If the sample is turbid, please centrifuge and precipitate it before use.
6. The kit used should be disposed of as latent infective material, and all samples, reagents and latent contaminants should be disinfected and disposed of according to relevant local regulations.
WWHS Assay list | Inflammation | |||||
cat#. | Product Item | Specimen | Reaction Time | Measure Range | Clinical Range | Intended Use |
10 | CRP / hs-CRP | WB/Serum/Plasma | 3min. | 0.5-200mg/L | CRP<10mg/L,hs-CRP<1mg/L | nonspecficity inflammatory marker. |
11 | SAA | Serum | 5min. | 1-200mg/L | <10mg/L | inflammation&infection. |
12 | PCT | WB/Serum/Plasma | 10min. | 0.2-100ng/ml | <0.5ng/ml | Sepsis |
13 | CRP+SAA | WB/Serum/Plasma | 5min. | same with single item | same with single item | inflammation&infection. |
14 | IL-6 | WB/Serum/Plasma | 10min. | 5-4000pg/ml | 10pg/ml | diabetes,rheumatoid arthritis,etc |
Interpretation of Test Results
1. The kit can be used for auxiliary test only. If test result is abnormal, retest timely and judge combined with clinical symptoms.
2. For samples whose cTnI concentration is lower than 0.1ng/mL and higher than 40ng/mL, test result is “<0.1ng/mL” and “>40ng/mL” respectively.
Manual of WWHS POCT Test Kit Procedure
1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
2. Start Nir-1000 dry fluorescence immunoassay analyzer according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
4. Place the test card on a clean horizontal table and mark it horizontally.
WWHS NIR-1000 Smarter Operation
1. High Quality: Imported Major Components with Advanced German Technology
2.User-Friendly Design: 7 Inch touch screen, great touch feeling, simple graphic interface
3. Built-In Lithium Battery: High Mobility for first aid&amulance
4. Two Test Mode: Internal&External mode for different clinical needs
5. Smart Report: Auto Printing
6. Visual Results: Able to connect with LIH/HIS
Send your inquiry directly to us