SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette

SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette

SAA Rapid Test kit

Rapid Diagnostics IVD Test Kit

Place of Origin:

CN

Brand Name:

WWHS

Certification:

CE

Model Number:

SAA

Contact Us

Request A Quote
Product Details
Product Name:
SAA Rapid Test Kit
Manufacturer:
WWHS Biotech INC
Application In:
WWHS NIR-1000
Package:
25 Tests
Storage:
At Room Temperature
Advantage:
High Sensitivity
Reactivity:
Human
Formal Name:
Serum Amyloid A Protein
Usage:
Inflammation
Production Capacity:
5 Million A Year
Payment & Shipping Terms
Minimum Order Quantity
1000
Price
US 1.50 - 2.50 Kit
Packaging Details
Colorful Paper Box
Delivery Time
7 Days
Payment Terms
T/T
Supply Ability
50000 Kits per Week
Product Description

【Product name】

Diagnostic Kit for C-reactive Protein and Serum Amyloid A protein(Immunochromatographic assay)

 

【Packing specification】

25 Tests/kit

 

【Intended use】

The kit is used for quantitative determination of C-reactive protein (CRP) and Serum Amyloid A protein (SAA) in human whole blood, plasma and serum. SAA and CRP are sensitive indicators reflecting infectious diseases.

 

【Test principle】

The CRP/SAA Rapid Test is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of CRP and SAA. The CRP or SAA antigen in the sample was first bound with the conjugated compound of fluorescent labeled CRP or SAA monoclonal antibody, then moved and combined with another CRP or SAA monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.

 

【Components】

Name Quantity Component
Test cards 25 It is composed of fluorescent pad (coated with fluorescently-labeled CRP/SAA monoclonal antibody), nitrocellulose membrane (coated with CRP/SAA monoclonal antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent 25 (1.0mL/ tube) Phosphate buffer
ID card 1 With specific stand curve file

The components in different batches of kits cannot be used interchangeably.

 

【Storage conditions and validity】

The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

The production date, batch number and expiration date are shown in the outer package of the product.

 

【Applicable instrument】

NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.

 

【Sample requirements】

  1. Plasma, serum and whole blood can be used as samples. The whole blood should be collected in a tube containing heparin, citrate or EDTA as the anticoagulant. If the serum procedure is used, collect blood in a tube without anticoagulant and allow clotting. Hemolyzed samples should not be used.
  2. Venous blood was collected according to routine laboratory methods to avoid hemolysis.
  3. It is highly recommended to use fresh samples instead of keeping the samples at room temperature for a long time. After samples were collected, the detection should be completed within 4 hours at room temperature (15℃~30℃). The whole blood sample can be stored at 2℃~8℃ for 48 hours. Plasma and serum samples can be stored at 2℃~ 8℃ for 7 days, -20℃ for 30 days.
  4. Before testing, the sample should return to room temperature (15℃~30℃). The frozen samples should be completely thawed, rewarming and mixed evenly before use. Repeated freeze-thaw cycles should be avoided.

【Test procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser and correctly select the corresponding sample type on the instrument.
  3. Take out the ID card, make sure that the batch number of the ID card is consistent with that of the test card, and insert the ID card into the ID card port of the instrument.
  4. Take out the test card from the aluminum foil bag and use it within 15 minutes.
  5. Place the test card on a clean horizontal table and mark it horizontally.
  6. Mix 10 µL of patient sample with 1.0mL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
  7. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser and click the “instant test” button to read the results at 5 minutes after addition of samples.

【Reference interval】

CRP normal reference value is less than 10.0mg/L and SAA normal reference value is less than 10.0mg/L. It is strongly recommended that each laboratory should determine its own normal and abnormal values.

 

【Interpretation of test results】

  1. This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
  2. For samples with CRP concentration lower than 1.00mg/L and higher than 200.00mg/L, the detection results are reported as "<1.00mg/L"and ">200.00mg/L", respectively.
  3. For samples with SAA concentration lower than 1.00mg/L and higher than 200.00mg/L, the detection results are reported as "<1.00mg/L"and ">200.00mg/L", respectively.

【Limitation of rest method】

  1. This kit is only used to detect human serum/plasma/whole blood samples
  2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
  3. The content of triglyceride in the sample shall not exceed 15mg/mL, the content of hemoglobin shall not exceed 5mg/mL, and the content of bilirubin shall not exceed 0.5mg/mL, and CRP relative deviation of the test results shall not exceed ±10%, SAA relative deviation of the test results shall not exceed ±15%.

4. When the concentration of CRP in the sample is less than 400mg/L, the concentration of SAA in the sample is less than 400mg/L, there is no hook effect.

  1. There was no HAMA effect when the concentration of human anti rat in the sample was less than 50ng/ml.
  2. When RF concentration of samples is less than 2000IU/mL, CRP relative deviation of the test results shall not exceed ±10%, SAA relative deviation of the test results shall not exceed ±15%.

【Performance】

1. Limits of detection

CRP: No higher than 1.00mg/L; SAA: No higher than 1.00mg/L.

2. Accuracy

CRP: the relative deviation from the target value is limited to ±10.0%;

SAA: the relative deviation from the target value is limited to ±15.0%.

3. Repeatability

CRP: the within assay coefficient of variations are within 10.0%;

SAA: the within assay coefficient of variations are within 15.0%.

4. Batch-to-batch variation

CRP: the extreme difference are within 15.0%; SAA: the extreme difference are within 15.0%.

5. Linearity range

CRP: Within the linear range(1.00~200.00)mg/L, the linear correlation coefficient R≥0.990;Within the linear range(1.00~ 5.00)mg/L, the linear absolute deviation is limited to ±0.50 mg/L;Within the linear range(5.00~ 200.00)mg/L, the linear relative deviation is limited to ±10.0%.

SAA: Within the linear range (1.00~ 200.00)mg/L, the linear correlation coefficient R≥0.990.

 

【Note】

1. The kit can be used for in vitro diagnosis only.

2. Test card and buffer solution are single-use and they cannot be reused.

3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

4. Take the test card out of the aluminum foil bag and carry out experiment in 15min. Do not place it in the air for a long time to avoid dampness.

5. It is required to strictly comply with the requirements for sample collection and storage. If the sample is turbid, please centrifuge and precipitate it before use.

The kit used should be disposed of as latent infective material, and all samples, reagents and latent contaminants should be disinfected and disposed of according to relevant local regulations.

 

SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette 0SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette 1

 

Note:


1) Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in
result. Each user should obtain their own standard curve.
2) If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
3) If specimens generate values higher than the highest standard, dilute the specimens and repeat the assay

 

Assay list          
 Inflammation          
cat#. Product Item Specimen Reaction Time Measure Range Clinical Range Intended Use
10 CRP / hs-CRP WB/Serum/Plasma 3min. 0.5-200mg/L CRP<10mg/L,hs-CRP<1mg/L nonspecficity inflammatory marker.
11 SAA Serum 5min. 1-200mg/L <10mg/L inflammation&infection.
12 PCT WB/Serum/Plasma 10min. 0.2-100ng/ml <0.5ng/ml Sepsis
13 CRP+SAA WB/Serum/Plasma 5min. same with single item same with single item inflammation&infection.
14 IL-6 WB/Serum/Plasma 10min. 5-4000pg/ml 10pg/ml diabetes,rheumatoid arthritis,etc

 

SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette 2SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette 3SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette 4SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette 5SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette 6SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette 7SAA Rapid Test kit FIA POCT Rapid Diagnostics IVD Human Test Cassette 8

 

Manual of WWHS POCT Test Kit Procedure


1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
2. Start Nir-1000 dry fluorescence immunoassay analyzer according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
4. Place the test card on a clean horizontal table and mark it horizontally.
5. Mix 100 μL of patient sample with 300μL of sample diluent. Apply 100 μL of diluted samples to the well of the test card.
6. Insert the test card into Nir-1000 dry fluorescent immunoanalyzer, read and record the results at 15 minutes after addition of samples, then dispose of used test appropriately.

 

FAQ:

 

1. What is the MOQ?

 

Generally if you choose the different products, our minimum order qty. also will be different. One sample available.

 

2. What about the delivery time?

 

The goods need 7-21 work days to be made upon deposit.

 

3. Does your product have any warranty?

 

Yes, we offer 6 months limited warranty for our products.

 

Damage due to misuse, ill treatment and unauthorized modifications and repairs are not covered by our warranty.

 

4. What's your payment method?

 

We usually accept the payment methods include PayPal, TT, and Western Union.

 

50% deposit in advance and balance before shipping. Buyer can choose which payment ways that you accept.

 

PayPal is most useful and safe, please don’t refuse PayPal fee when you choose PayPal.

 

5. What's your shipping method?

 

We provide comprehensive shipping methods.

 

For small quantity orders we ship by DHL Air-Express, or EMS/TNT/UPS/FEDEX Express service, it is safe and fast.

 

For large quantity orders we ship by Air transportation or sea transportation, we can also ship order to buyer’s cargo agent in China.

Send your inquiry directly to us

Privacy Policy China Good Quality POCT Test Kit Supplier. Copyright © 2021-2024 fiapoct.com . All Rights Reserved.