Send Message
Home > products > Cardiac Testing Kit >
Lipoprotein-Associated Phospholipase A2 Lp-PLA2 Rapid Test Kit 5000 Tests/Day

Lipoprotein-Associated Phospholipase A2 Lp-PLA2 Rapid Test Kit 5000 Tests/Day

NIR-1000 Analyser Cardiac Testing Kit

Lp-PLA2 Cardiac Testing Kit

5000 Tests/Day Lp-PLA2 Rapid Test Kit

Place of Origin:

CN

Brand Name:

WWHS

Certification:

CE

Model Number:

Lp-PLA2

Contact Us

Request A Quote
Product Details
Product Name:
Lp-PLA2 Rapid Test Kit
Diagnosis:
CHD
Package:
25T
Reactivity:
Human
Throughput:
5000 Tests/Day
Usage:
Cardiac Diagnostic
Main Application:
Physical Examination Center
Synonymous:
Lipoprotein Phospholipase A2
Formal Name:
Lipoprotein-associated Phospholipase A2
Application In:
WWHS NIR-1000 Dry Fluoroimmunoassay Analyser
Payment & Shipping Terms
Minimum Order Quantity
1000
Price
US 1.50 - 2.50 Kit
Packaging Details
Colorful Paper Box
Delivery Time
7 Days
Payment Terms
T/T
Supply Ability
50000 Kits per Week
Product Description

Product name           Lp-PLA2.pdf

Diagnostic Kit for Lipoprotein-Associated Phospholipase A2(Immunochromatographic assay)

 

【Intended use】

1,This kit is used for quantitative determination of Lp-PLA2 in human whole blood, plasma and serum.

Clinically.

       2.it is mainly used to evaluate the degree of atherosclerosis inflammation and the auxiliary diagnosis of cardiovascular and cerebrovascular diseases caused by atherosclerosis.

 

【Test principle】

1,The Lp-PLA2 Rapid Test is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of Lp-PLA2.

2,The Lp-PLA2 antigen in the sample was first bound with the conjugated compound of fluorescent labeled Lp-PLA2 monoclonal antibody, then moved and combined with another Lp-PLA2 monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane.

3,The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.

4,The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months.

 

【Components】

Name Quantity Component
Test cards 25 It is composed of fluorescent pad (coated with fluorescent labeled Lp-PLA2 monoclonal antibody), nitrocellulose membrane (coated with Lp-PLA2 monoclonal antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent 25(600μL/tube) Phosphate buffer
ID card 1 With specific stand curve file
 

The components in different batches of kits cannot be used interchangeably.

 

【Sample requirements】

  1. Plasma, serum and whole blood can be used as samples. The whole blood should be collected in a tube containing heparin, citrate or EDTA as the anticoagulant. If the serum procedure is used, collect blood in a tube without anticoagulant and allow clotting. Hemolyzed samples should not be used.
  2. Venous blood was collected according to routine laboratory methods to avoid hemolysis.
  3. It is highly recommended to use fresh samples instead of keeping the samples at room temperature for a long time. After samples were collected, the detection should be completed within 4 hours at room temperature (15℃~30℃). The whole blood sample can be stored at 2℃~8℃ for 24 hours. Plasma and serum samples can be stored at 2℃~ 8℃ for 7 days, -20℃for 30 days.
  4. Before testing, the sample should return to room temperature (15℃~30℃). The frozen samples should be completely thawed, rewarming and mixed evenly before use. Repeated freeze-thaw cycles should be avoided.

 

 

【Reference interval】

Healthy non-pregnant adults are expected to have serum Lp-PLA2 values below 175.00ng/mL. It is strongly recommended that each laboratory should determine its own normal and abnormal values based on population.

 

【Interpretation of results】

  1. This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
  2. For samples with Lp-PLA2 concentration lower than 10.00ng/mL and higher than 900.00ng/mL, the detection results are reported as "<10.00ng/mL" and "> 900.00ng/mL", respectively.

 

 

Lipoprotein-Associated Phospholipase A2 Lp-PLA2 Rapid Test Kit 5000 Tests/Day 0

 

WWHS Assay list          
Cardiac          
cat#. Product item Specimen Reaction Time Measure Range Clinical Range Itended Use
1 cTnI WB/Serum/Plasma 12min. 0.1-40ng/ml <0.3ng/ml several heart diseases including myocardial infarction and heart failure.
2 Myo WB/Serum/Plasma 12min. 5-400ng/ml <58ng/ml acute myocardial infarction (AMI) in early stage.
3 CK-MB WB/Serum/Plasma 12min. 1-200ng/ml <5ng/ml acute myocardial infarction (AMI) in early stage.
4 NT-proBNP WB/Serum/Plasma 10min. 20-35000pg/ml Under 75:0~347pg/mL,
Over 75:0~449pg/mL
heart failure .
5 D-Dimer WB/Plasma 10min. 40-10000ng/ml <500ng/ml disseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
6 cTnI+Myo+CKMB WB/Serum/Plasma 12min. same with single item same with single item Triple marker of myocardial infarction.
7 ST2 WB/Serum/Plasma 10min. 10-400ng/ml <35ng/ml heart failure .
8 Lp-PLA2 WB/Serum/Plasma 10min. 10-900ng/ml <175ng/ml Risk evaluation of ACS and atherosclerotic ischemic stroke patients.
9 S100-β WB/Serum/Plasma 10min. 0.05-10ng/ml <0.2ng/ml Cerebral infarction, cerebral injury.
Inflammation          
10 CRP / hs-CRP WB/Serum/Plasma 3min. 0.5-200mg/L CRP<10mg/L,hs-CRP<1mg/L nonspecficity inflammatory marker.
11 SAA Serum 5min. 1-200mg/L <10mg/L inflammation&infection.
12 PCT WB/Serum/Plasma 10min. 0.2-100ng/ml <0.5ng/ml Sepsis
13 CRP+SAA WB/Serum/Plasma 5min. same with single item same with single item inflammation&infection.
14 IL-6 WB/Serum/Plasma 10min. 5-4000pg/ml 10pg/ml diabetes,rheumatoid arthritis,etc
Thyroid Hormone          
15 TSH Serum/Plasma 15min. 0.3-100mU/L 0.35-5mU/L hyperthyroidism and hypothyroidism
16 TT3 Serum/Plasma 15min. 0.5-10nmol/L 1.3-3.1nmol/L thyroid dysfunction
17 TT4 Serum/Plasma 15min. 5-300nmol/L 66-181nmol/L thyroid dysfunction
18 FT3 Serum/Plasma 15min. 1-100pmol/L 4-10pmol/L thyroid dysfunction
19 FT4 Serum/Plasma 15min. 5-300pmol/L 19-39pmol/L thyroid dysfunction
Tumor Marker          
20 AFP Serum/Plasma 15min. 2.5-200ng/ml <20ng/ml pregnancy cancer
21 CEA Serum/Plasma 15min. 1-200ng/ml <5ng/ml colon cancer, colorectal cancer,etc.
22 NSE Serum/Plasma 15min. 1-400ng/ml <16ng/ml non-small cell lung cancer
23 FOB fecal specimens 10min. 50-1000ng/ml <100ng/ml Abnormal recessive gastrointestinal bleeding
24 PG II Serum/Plasma 15min. 1-100ug/L PGI/PGII>3.0 gastric abnormalities
25 PG I Serum/Plasma 15min. 2.5-200ug/L >70ng/ml gastric abnormalities
26 TPSA Serum/Plasma 15min. 0.5-40ng/ml <4ng/ml prostate cancer
27 FPSA Serum/Plasma 15min. 0.1-10ng/ml <1ng/ml prostate cancer
28 CA12-5 Serum/Plasma 15min. 20-500U/ml <35U/ml ovarian cancer
29 CA15-3 Serum/Plasma 15min. 10-400U/ml < 25 U/mL breast cancer
30 HE4 Serum/Plasma 15min. 50-2000pmol/L <140 pmol/L ovarian cancer
31 CA19-9 Serum/Plasma 15min. 10-400U/ml < 27 U/mL pancreatic cancer
32 β-HCG Serum/Plasma 15min. 5-400mIU/ml <10 mIU/mL Early pregrancy, ectopic HCG cancer,incomplete abortion
33 CK19(Cyfra21-1) Serum/Plasma 15min. 0.5-50ng/ml <2.5ng/ml non-small cell lung cancer
Fertility          
34 HCG / β-HCG Serum/Plasma 10min. 5-20000mIU/ml <5 mIU/mL early pregrancy.
35 AMH Serum/Plasma 10min. 0.1-16ng/ml Male: 20-60 years old, 0.92-13.89 ng/mL
Female: 20-29 years old, 0.88-10.35 ng/mL
30-39 years old, 0.31-7.86 ng/mL 40 -50 years old, <5. 07 ng/mL
ovarian reserve level
Gastrointestinal            
36 FOB fecal specimens 10min. qualitative qualitative gastrointestinal hemorrhage.
37 TRF fecal specimens 10min. qualitative qualitative gastrointestinal hemorrhage.
38 FOB+TRF fecal specimens 10min. qualitative qualitative gastrointestinal hemorrhage.
Infection            
39 C.Pneumonia WB/Serum/Plasma 15min. qualitative qualitative CP infection
40 M.Pneumonia WB/Serum/Plasma 15min. qualitative qualitative MP infection
41 Covid-19 Antigen nasal swab, throat swab or nasal wash/aspirate specimens 15min. qualitative qualitative respiratory tract
42 Covid-19 Ab IgG/IgM WB/Serum/Plasma 15min. qualitative qualitative respiratory tract
43 FluA nasal swab, throat swab or nasal wash/aspirate specimens 15min. qualitative qualitative respiratory tract
44 FluB nasal swab, throat swab or nasal wash/aspirate specimens 15min. qualitative qualitative respiratory tract
Renal Injury            
45 CysC WB/Serum/Plasma 5min. 0.4-9mg/L 0.5-1.1mg/L renal function
46 NGAL Urine 10min. 10-1500ng/mL <132ng/mL acute kidney injury.
Other            
47 FERR Serum 5min. 10-500ng/ml Male:24ng/mL~335ng/mL,
Female:11ng/mL~307ng/mL
iron metabolism related diseases, such as hemochromatosis and iron deficiency anemia
48 HbA1c WB 10min. 4%-14% 4%-6% diabetes
49 VD Serum/Plasma 15min. 8-70ng/mL 19-57ng/mL fetation

 

 

 

 