CA125 25 Tests/Kit Test Kit Tumor Marker FIA POCT In Human Whole Blood

CA125 25 Tests/Kit Test Kit Tumor Marker FIA POCT In Human Whole Blood

25 Tests/Kit CA125 home test kit

Blood CA125 home test kit

Tumor Marker CA125 Test Kit

Place of Origin:

CN

Brand Name:

WWHS

Certification:

ISO13485, CE

Model Number:

CA125

Contact Us

Request A Quote
Product Details
Product Name:
CA125
Package:
25 Tests
Warranty:
12 Months
Manufacturer:
WWHS Biotech
Reactivity:
Human
Feature:
High Sensitivity, High Accuracy
Application:
Tumor Marker Detection
Throughput:
500 Tests/hour
Payment & Shipping Terms
Minimum Order Quantity
2000
Price
US 1.60-2.50 Kit
Packaging Details
Colorful Paper Box
Delivery Time
10 Days
Payment Terms
L/C, T/T
Supply Ability
35000 Kits per Week
Product Description

 

【Product name】CA125.pdf

 Carbohydrate Antigen 125(CA125)Rapid Quantitative Test(Fluorescence immunoassay)

 

【Package specification】

 25 Tests/kit

 

【Components】

Name Quantity Component
Test cards 25 It is composed of fluorescent pad (coated with fluorescent labeled CA125 monoclonal mouse antibody), nitrocellulose membrane (coated with CA125 monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent 25(300μL/tube) Phosphate buffer
ID card 1 With specific stand curve file
 

The components in different batches of kits cannot be used interchangeably.

 

【Storage conditions and validity】

The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

The production date, batch number and expiration date are shown in the outer package of the product.

 

【Applicable instruments】

NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.

 

【Procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
  3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
  4. Place the test card on a clean horizontal table and mark it horizontally.
  5. Mix 100 µL of patient sample with 300µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
  6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, read and record the results at 10 minutes after addition of samples, then dispose of used test appropriately.

【Performance】

1. Limits of detection,No more than 20U/mL.

2. Accuracy,The relative deviation from the target value is within ±15%.

3. Precision,The within and between assay coefficient of variations are within 15%.

4.Linear range,Within the linear range (20-500U/mL), the linear correlation coefficient R≥0.990.

 

【Note】

1. This kit is only used for in vitro diagnosis.

2. The test card and sample diluent are disposable and cannot be reused.

3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.

5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.