HE4 Rapid Quantitative Fluorescence Immunoassay Test Cassette in human

HE4 Rapid Quantitative Fluorescence Immunoassay Test Cassette in human

HE4 fluorescence immunoassay rapid quantitative test

fluorescence immunoassay rapid quantitative test Cassette

HE4 Rapid Quantitative Test Cassette

Place of Origin:

CN

Brand Name:

WWHS

Certification:

ISO13485

Model Number:

HE-4

Contact Us

Request A Quote
Product Details
Product Name:
HE4 Rapid Quantitative Test Cassette
Sample Buffer:
25 Vials
Warranty:
12 Months
Applicable Instruments:
NIR-1000 Dry Fluorescent Immunoassay Analyzer
Manufacturer:
WWHS Biotech INC
Usage:
Tumor Marker
Reactivity:
Human
Sample Type:
Serum / Plasma
Feature:
High Sensitivity
Annual Capacity:
3 Million A Year
Payment & Shipping Terms
Minimum Order Quantity
1000
Price
US 1.50-2.50 Kit
Packaging Details
Colorful Paper Box
Delivery Time
10 Days
Payment Terms
L/C, T/T
Supply Ability
20000 Kits per Week
Product Description

HE4 Rapid Quantitative Fluorescence Immunoassay Test Cassette FIA POCT IVD

 

Sample requirements


1. Plasma, serum and whole blood can be used as samples. The whole blood should be collected in a tube containing heparin, citrate or EDTA as the anticoagulant. If the serum procedure is used, collect blood in a tube without anticoagulant and allow clotting. Hemolyzed samples should not be used.
2. Venous blood was collected according to routine laboratory methods to avoid hemolysis.
3. It is highly recommended to use fresh samples instead of keeping the samples at room temperature for a long time. After samples were collected, the detection should be completed within 4 hours at room temperature (15℃~30℃). The whole blood sample can be stored at 2℃~8℃ for 24 hours. Plasma and serum samples can be stored at 2℃~ 8℃ for 7 days, -20℃for 30 days.
4. Before testing, the sample should return to room temperature (15℃~30℃). The frozen samples should be completely thawed, rewarming and mixed evenly before use. Repeated freeze-thaw cycles should be avoided.

 

Importance of IVD

 

The importance of in vitro diagnosis in life and health is mainly reflected in that no

matter healthy people, asymptomatic and symptomatic people and people with chronic

diseases are inseparable from diagnostics, and diagnosis runs through the whole medical

cycle. In particular, modern medicine has entered the era of precision medicine, and the

core of precision medicine is accurate diagnosis.

 

WWHS POCT Assay List

 

 Tumor Marker          
cat#. Product Item Specimen Reaction Time Measure Range Clinical Range Intended Use
18 AFP Serum/Plasma 15min. 2.5-200ng/ml <20ng/ml pregnancy cancer
19 CEA Serum/Plasma 15min. 1-200ng/ml <5ng/ml colon cancer, colorectal cancer,etc.
20 NSE Serum/Plasma 15min. 1-400ng/ml <16ng/ml non-small cell lung cancer
21 FOB fecal specimens 10min. 50-1000ng/ml <100ng/ml Abnormal recessive gastrointestinal bleeding
22 PG II Serum/Plasma 15min. 1-100ug/L PGI/PGII>3.0 gastric abnormalities
23 PG I Serum/Plasma 15min. 2.5-200ug/L >70ng/ml gastric abnormalities
24 PSA Serum/Plasma 15min. 0.5-40ng/ml <4ng/ml prostate cancer
25 FPSA Serum/Plasma 15min. 0.1-10ng/ml <1ng/ml prostate cancer
26 CA12-5 Serum/Plasma 15min. 20-500U/ml <35U/ml ovarian cancer
27 CA15-3 Serum/Plasma 15min. 10-400U/ml < 25 U/mL breast cancer
28 HE4 Serum/Plasma 15min. 50-2000pmol/L <140 pmol/L ovarian cancer
29 CA19-9 Serum/Plasma 15min. 10-400U/ml < 27 U/mL pancreatic cancer
30 β-HCG Serum/Plasma 15min. 5-400mIU/ml <10 mIU/mL Early pregrancy, ectopic HCG cancer,incomplete abortion
31 CK19(Cyfra21-1) Serum/Plasma 15min. 0.5-50ng/ml <2.5ng/ml non-small cell lung cancer

 

HE4 Rapid Quantitative Fluorescence Immunoassay Test Cassette  in human 0

 

 

HE4 Rapid Quantitative Fluorescence Immunoassay Test Cassette  in human 1

 

Interpretation of results


1. This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
2. For samples with AFP concentration lower than 2.5ng/ml and higher than 200ng/ml, the detection results are reported as "< 2.5ng/ml" and "> 200ng /ml", respectively.


Limitations of methods


1. This kit is only used to detect human plasma/whole blood samples
2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
3. The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.
4. When the concentration of AFP in the sample is less than 20000ng/ml, there is no hook effect.
5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
6. When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.

Applicable Instrument

 

WWHS NIR-1000 dry fluoroimmunoassay analyser

 

 

Send your inquiry directly to us

Privacy Policy China Good Quality POCT Test Kit Supplier. Copyright © 2021-2024 fiapoct.com . All Rights Reserved.