WWHS NGAL High Sensitivity Assist Quantitative Determination Of Neutrophil Gelatinase-Associtated Lipocalin

WWHS NGAL High Sensitivity Assist Quantitative Determination Of Neutrophil Gelatinase-Associtated Lipocalin

NGAL Rapid Test Kit 25 Vials

One Step Assay NGAL Rapid Test Kit

NGAL Rapid Test Kit High Sensitivity

Place of Origin:

CN

Brand Name:

WWHS

Certification:

ISO 13485, CE

Model Number:

NGAL

Contact Us

Request A Quote
Product Details
Product Name:
NGAL Rapid Test Kit
Storage:
Room Temperature
Sample Buffer:
25 Vials
Manufacturer:
WWHS BIOTECH INC
Type:
One Step Assay
Reactivity:
Human
Advantage:
High Sensitivity
Application In:
WWHS NIR-1000
Keywords:
High Stability, High Accuracy
Package:
20 Tests
Payment & Shipping Terms
Minimum Order Quantity
1000
Price
US 1.50-2.99 Kit
Packaging Details
Colorful Paper Box
Delivery Time
7 Days
Payment Terms
L/C, T/T
Supply Ability
20000 Kits per Week
Product Description

【Product name】NGAL.pdf

Diagnostic Kit for Neutrophil gelatinase-associtated lipocalin(Immunochromatographic assay)

 

【Intended use】

The kit is used for quantitative determination of Neutrophil gelatinase-associtated lipocalin (NGAL) in human urine. Clinically, it is mainly used to assist in the diagnosis of renal function injury.

 

【Test procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser and correctly select the corresponding sample type on the instrument.
  3. Take out the ID card, make sure that the batch number of the ID card is consistent with that of the test card, and insert the ID card into the ID card port of the instrument.
  4. Take out the test card from the aluminum foil bag and use it within 15 minutes.
  5. Place the test card on a clean horizontal table and mark it horizontally.
  6. Mix 100 µL of urine sample with 300µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
  7. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser and click the “instant test” button to read the results at 10 minutes after addition of samples.     

 

     【Performance】

  1. Limits of detection
  2. No higher than 10.00 ng/mL.

  3. Accuracy
  4. The relative deviation from the target value is limited to ±15.0%.

  5. Repeatability
  6. The within and between assay coefficient of variations are within 15.0%.

  7. Linearity range
  8. Within the linear range (10.00~ 1500.00)ng/mL, the linear correlation coefficient R≥0.990.

 

 

 WWHS Assay list          
 Renal Injury          
cat#. Product item Specimen Reaction Time Measure Range Clinical Range Itended Use
45 CysC WB/Serum/Plasma 5min. 0.4-9mg/L 0.5-1.1mg/L renal function
46 NGAL Urine 10min. 10-1500ng/mL <132ng/mL acute kidney injury.

 

 